The cylinder strength It is not enough and does production efficiency affect? The power of the Press is unstableWhat increases the defective product rate? These are common problems caused by a insufficient local air pressure.
It is not necessary to change the air compressor: just install a pressure multipliers at the point where greater pressure is required to solve the problem.

1. What is a pressure multipliers?
The VBA pressure multipliers It is a highly efficient amplifier device that can duplicate o Quadruply the pressure of compressed air without the need for an external power supply.
Working principle: The vba pneumatic pressure multiplier uses a double piston structure y aerodynamic principles To achieve supercharging. Divide the input gas source into two ways and enter the cylinder, pushing the piston and compressing the gas to generate a high pressure outlet.


2. Comparison of VBA Series Pressure Multipliers
| Serie | Port size | Pressure rise ratio | Caudal Máximo (L/Min (ANR)) | Adjustment pressure (MPA) | Pressure adjustment mechanism | Installation |
| VBA10A | 1/4 | 2 times | 230 | 0,2-2,0 | Operated by knob With relief mechanism | Horizontal |
| VBA20A | 3/8 | 1000 | 0,2-1,0 | |||
| VBA40A | 1/2 | 1900 | 0,2-1,0 | |||
| VBA11A (VBA-X3239) | 1/4 | 4 times (fixed) | 90 | 0,8-2,0 | Fixed type | Horizontal/ Vertical |
3. VBA11A efficient pressure multipliers
- He modelo VBA-X3239 Increase air pressure to 4 times.
- Long useful life: 50 million of cycles or more.
- Integrated silencer.
- You can mount a magnetic sensor at the top to count the driving number.
- The fixed impulse ratio eliminates the need for a regulatory knob.
- Interchangeable assembly with existing products (VBA serial pressure multipliers).
- Mounting horizontal y vertical available.

4. How to adjust the air pressure multiplier?
| Models | Adjustment method | Operation instructions | Application | |||
| Manual type | Operated by knob | 1. Manually turn the regulation knob to adjust the pressure. 2. Turn the knob in time sense → Increase The output pressure. 3. Turn the knob in Anti -Horary sense → Decrease The output pressure. 4. Tighten the contractor after adjusting the desired pressure. | 1. Suitable for manual control by personnel in situ. 2. Intuitive operation, ideal for the initial installation of the equipment or for frequent adjustments in situ. | |||
| Air controlled type | Pilot air control | 1. An external sign of pilot air pressure (Pilot air) It is introduced into the control port. 2. The pneumatic booster uses this pressure signal to adjust the output pressure. 3. The higher the pilot air pressure, the greater the output pressure (usually in a ratio Lineal The proportional). | 1. appropriate for remote or automatic control systems. 2. It is frequently used with ITV electropneumatic regulator o solenoid valves To achieve a remote pressure adjustment. 3. Improves system automation. | |||
| Fixed type | Fixed multiplication ratio | 1. Factory adjusted multiplication ratio (eg, 2x o 4x). 2. It depends on the input pressure; There is no adjustment mechanism. 3. If a different output pressure is required, the corresponding fixed model must be replaced. | 1. appropriate for applications where the pressure is fixed and No frequent adjustments are required. 2. Avoid malfunction and improve system stability. | |||
5. Notes on the use of VBA
① If the output pressure of the supercharging valve exceeds 1.0 mpa, verify the pressure specifications of the connectors, las Pipes and the Valves area.
② An overcharge pressure of 2 to 4 times higher; Pay attention to handle adjustment.
③ When installing a lubricator, this must be installed in the Departure side, and a filter device is also required on the output side.
④ The exhaust pipe It must be laid separately to avoid background.
⑤ When transporting the unit, hold it at both ends; Never for the central handle.
FAQ
1. How do I determine the necessary supercharging relationship?
This requires a calculation based on the Input pressure of the system and the Output pressure desired VPC has professional technicians to perform precise calculations.
2. How to install the pressure multiplier?
To obtain detailed instructions for the installation of the VBA pressure multipliers and the VBAT compressed air ANQUE, see this article: How to install the pressure multiplier?
Video installation tutorial:
3. What fluids supports VBA pressure?
Admits several fluids, as aire, nitrogen, Hydraulic oil and water. Specific compatibility must be confirmed according to product specifications.
4. What is the difference between manual and tire models?
Manual models can only Configure in situ, while tires can be operated remotely using an independent pressure reducing pilot valve.
If you have any questions about pressure multipliers, or want a recommendation of a specific model or a wholesale purchase quotation, comuníquese con VPC Pneumatic.