Skip to content Skip to footer

VT317 series 3-way direct drive NC/NO solenoid valve

1. It offers versatility through the NC/NC 3 -wire so -road so -road sootable drive, which integrates 6 functions (universal portage type) including closed normal valve (N.C.), Normal Open Valve (N.O.), Divicing valve, selector valve, among others.
2. The VO series collector solenoid valve can pass without normally closed effort (N.C.) to normally open (N.A.) just by rotating the switch cover.

Description

■ Features

The Seat sole valve of 3 VT317 ports is often used in applications that require precise control of the fluid flow.

  1. ELECTROVALVULA NC/NA DIRECT ACTION OF 3 WAYS VT317 Series Compact of the valve body that provides high flows.
  2. The obturator and seat design can provide a very effective seal, reducing leaks and improving efficiency.
  3. Adequate for use in vacuum and pneumatic applications.
  4. A single valve with 6 valve functions.
  5. The selective connection can provide 6 valve functions, such as Valve N.C., Valve N.O., Divicing valve, selector valve, etc.

■ How to order VT317 Electrovalvula series

3-way direct drive NC/NO solenoid valve

■ Collector

ModelType of applicable collectorAccessory
VO317(-Q)Escape with the individualO -ring (4 units.)* Hexagonal screw (2 units.)

* It does not apply to the "type of continuous work". See accessories on page 5.

■ Specs

Drive type2 position monostable type direct drive
Working mediumAire
Working pressure0 0.9 MPa
Working temperature-10 to 50°C (No freezing)
Response time*¹)30 ms or less (at 0.5 mpa pressure)
Max frequency operating10 Hz
LubricationNot required (Use Class 1 lSO VG32 turbine oil, if lubricated.)
manual controlPush type (non-locking)
Mounting orientationNo restrictions
Resistance to impacts and vibrations*²)150/50 m/s
Boxdust proof
electrical entryPasacables, duct, duct terminal, DIN Terminal
Rated coil voltageAC (50/60 Hz)100V, 200V, 110V*, 220V*, 240V*
DC24V, 12V*
Allowable voltage fluctuation-15 to +10% of nominal voltage
APPEARING POWER*³)ACInrush19 go (50 Hz), 16 go (60 Hz)
Retention11 go (50 Hz), 7 go (60 Hz)
Electric consumption*³)DCNo indicator light: 6 W, with indicator light: 6.3 W
Light/SUPPRESSOR OF ABRETENSION
(Not applicable for the buttonhole type)
ACVaristor, neon bulb
DCVaristor, LED
(Neon bulb for 100 v or more)

* Semi-standard.
*1) Based on dynamic performance test, JIS B 8419: 2010. (Coil temperature: 20°C, at rated voltage, without surge suppressor)
*2) Impact resistance: No malfunctions occur when tested with a drop tester in the axial direction and at right angles to the main valve and armature in both energized and de-energized states each time for each condition. (Values ​​in the initial period)
Vibration resistance: No malfunctions occurred in a single sweep test between 45 and 1000 Hz. The test was performed in both on and off states in the axial direction and at right angles to the main valve and armature. (Values ​​in the initial period)
*3) At nominal voltage.
*4) The value is different for continuous duty type (VT307E), and energy saving type (VT307Y/W).
See the "Valve options" below. Make sure the dust and/or other foreign materials do not enter the valve through the unused port (for example, the exhaust port).

■ Flow characteristics

Valve model1→2(P→A)2→3(A→R)3→2(R→A)2→1(A→P)
C [dm³/(s·bar)]bCvC [dm³/(s·bar)]bCvC [dm³/(s·bar)]bCvC [dm³/(s·bar)]bCv
Vt3172,40,260,622,60,340,672,80,250,672,50,370,66
VT317V (Empty type spec.)
VT317E (type of continuous service)

* Values ​​for a unique valve unit. Differs in the case of the collector. See collector's specifications on page 5.

■ Valve options

Continuous service type: VT317E

The exclusive use of VT317E for continuous service with prolonged load is recommended.

▲ Caution

1. This model is for continuous duty, not high cycle rates. But even at low cycle rates, if you energize the valve more than once a day, please consult VPC.

2. Solenoid activation must be performed at least once every 30 days.

Vacuum specification type: VT317V

This vacuum model has fewer air leaks than the standard low pressure model. It is recommended for vacuum applications.

▲ Caution

1. Since this valve has slight air leaks, it cannot be used for vacuum retention (including positive pressure retention) in the pressure container.

The specifications different from the standard ones are as follows.

Operating pressure-101.2 kPa a 0.1 MPa

■ Dimensions

High vacuum solenoid valve
3 port solenoid valve direct drive

Subscribe for the updates!

[mc4wp_form id="461" element_id="style-11"]