FRL units with safety valve AC20-D to AC60-D series

Description

■ Features

Most of the features of the AC-A and AC-B models have been incorporated into the AC-D series filters: transparent bowl protection for full visibility, integrated pressure gauges and pressure switches, reduced maintenance space and change of Simplified elements in AF-D series filters.
1. Modular design with uniform body style. Interchangeable assembly with existing product.
2. Expanded range of pipe adapters, interfaces and modular pressure switches.
3. FRL units with AC20-D AC20-D Safety Valve A AC60-D The filter cartridges are easy to replace. The cartridge and filter bucket are integrated. They can be replaced manually.
4. Energy saving regulator. Pressure drop: Max. 50% improvement
5. Reduction of maintenance space: Max. 46% reduction
6. FRL units with AC20-D SERIAL SAFETY VALVE A AC60-D It is available on RC, NPT or G.

Order Example:

Option/semi-standard: Select one of each of options a to j.
Option/semi-standard symbol: When more than one specification is required, list them in alphanumeric order.
Model: AC30-F03DE1-16NR-D

■ Cómo ordenar AC20-D a AC60-D serie unidades FRL con válvula de seguridad

maintenance units
maintenance unit frl

*1) The drain guide is NPT1/8 (applicable to AC20-D) and NPT1/4 (applicable to AC30-D to AC60-D). The automatic drain port comes with a Φ3/8” One-touch fitting (applicable to AC30-D to AC60-D).
*2) Drain guide G1/8 (applicable to AC20-D) and G1/4 (applicable to AC30-D to AC60-D).
*3) When no pressure is applied, condensate that does not trigger the automatic drain mechanism will remain in the bucket. It is recommended to evacuate residual condensate before ending the day's operations.
*4) If the compressor is small [0.75 kW, discharge flow is less than 100 L/min (ANR)], air leakage may occur from the bleed cock during the start of operations. N.C type is recommended.
*5) When the pressure gauge is attached, a 1.0 MPa pressure gauge will be installed for the standard type (0.85 MPa). 0.4 MPa pressure gauge for 0.2 MPa type.
*6) Higher pressure than specified can be set in some cases, but use pressure within the specified range.
*7) A tank protector (polycarbonate) is supplied as standard.

*8) Protection of the tank as standard (nylon).
*9) Float type C and D automatic drain combination not available.
*10) Without valve function.
*11) The combination of metal bowl 2 and 8 is not offered.
*12) When chosen with W: air filter drain port, the drain cock of a lubricator will be with barb fittings.
*13) For pipe thread type: NPT Cannot be used with M: Round type pressure gauge (with color zone). Available upon special order. The digital pressure switch will be equipped with unit selection function, setting to psi initially.
*14) For options: E1, E2, E3, E4.
*15) : For pipe thread type: NPT only.
*16) △: Select with options: E1, E2, E3, E4.

■ Specs

ModelAC20-DAC30-DAC40-DAC40-06-DAC50-DAC60-D
ComponentAir filter[AF]AF20-DAF30-DAF40-DAF40-06-DAF50-DAF60-D
Regulator[AR]AR20-DAR30-DAR40-DAR40-06-DAR50-DAR60-D
Lubricator[AL]AL20-DAL30-DAL40-DAL40-06-DAL50-DAL60-D
Port size1/8, 1/41/4, 3/81/4, 3/8, 1/23/43/4, 11
Connection size
pressure gauge *¹) [AR]
1/8
Working mediumclean air
Working temperature*²)-5 to 60°C (No freezing)
Test pressure1,5Mpa
Max. Working pressure1,0Mpa
Minimum operating pressureN.C. [OF]0,1 MPa0,15MPa
N.O. [OF]—0,1 MPa
Nominal pressure range [AR]0,05 ~ 0,85Mpa
Nominal filtration degree [AF]5 µm
Compressed air purity classISO 8573-1:2010 [ 6 : 4 : − ]
Drainage capacity [AF]8 cm³25 cm³45 cm³
Min. Book*3) [Al]15 L/min (ANR)1/4 port size:
30 L/min (ANR)
1/4 port size:
30 L/min (ANR)
50 L/min (ANR)190 L/min
(ANR)
220 L/min
(ANR)
Port size 3/8:
40 L/min (ANR)
Port size 3/8:
40 L/min (ANR)
Port size 1/2:
50 L/min (ANR)
Oil capacity [AL]25 cm³55 cm³135 cm³
Recommended lubricant [AL]Class 1 turbine oil (ISO VG32)
Material of the Cuba [AF/Al]Polycarbonate
Tank protection [AF/AL]Semi-standard (Steel)Standard (polycarbonate)
Construction [AR]Relief type

*1) Connection threads for pressure gauge not available for Unit F.R.L. with recessed square type pressure gauge or with digital prisoner.
*2) -5 to 50°C for products with digital pressure switch.
*3) The flow rate is 5 drops or more/min under the following conditions: Inlet pressure of 0.5 MPa; Class 1 turbine oil (ISO VG32); Temperature at 20°C; Oil adjustment valve fully open.
For a circuit that repeatedly turns on and off on the outlet side, adjust so that the average air consumption per minute is equal to or greater than the minimum drip rate.

■ Dimensions

frl units
tratamiento de aire comprimido
FRL air preparation units
With 3-port pressure relief valve (V)
Filter-regulator-lubricator Compressor Without Pressure Gauge
High flow lubricator regulator filter
Pneumatic Filter Regulator Lubricator

PDF Catalog