Description
3 port valve DIRECT ACTION 3PA/3PB Series is built as a balanced pressure seat valve.
■ Features
The 3PA 3PA series of three pressurized direct action, with work pressures from 0.7 MPa to a low -100 kPa vacuum, facilitates the construction of low pressure/vacuum systems.
1. The port can be pressurized from any of the 3 ports.
2. 3 port valve DIRECT ACTION SWITCH 3PB/3PB BETWEEN NA and NC.
3. The seat and packaging of the valve of the rod assembly have the same diameter, so the pressure differential of each port is canceled by the internal hole of the rod assembly and the pressure is balanced both on and off.
■ Specs
Common specifications
| Model | 3PA1 | 3Pa2 | 3PB1 | 3PB2 |
|---|---|---|---|---|
| Port size | M5 | 1/8 | 1/8 | 1/8, 1/4 |
| Valve and operation | Direct action seat valve | |||
| Working medium | Compressed air, under vacuum | |||
| Max pressure of work | 0,70 MPa | |||
| Min. of work | -100 kPa | |||
| Test pressure | 1,05 MPa | |||
| Differential working pressure max. | 0,70 MPa | |||
| Room temperature | -5 to 50 ℃ (without freezing) | |||
| Working temperature | 5 a 50 ℃ | |||
| Lubrication | There's no need | |||
| Protection degree | dust proof | |||
| Vibration resistance | 50 m/s² o Menos | |||
| Blow resistance | 300 m/s² o Menos | |||
| Atmosphere | It cannot be used in environments with corrosive gases | |||
| Response time | 20 ms the least | |||
* 3 port valve DIRECT ACTION SERIES 3PA/3PB The response time is the value at a 0.5 MPa feed pressure, without lubrication and with connected feed. It depends on the pressure and quality of the lubricant.
Solenoid specifications
| Model | 3PA1 | 3Pa2 | ||
|---|---|---|---|---|
| 3PB1 | 3PB2 | |||
| Calibrated tension | AC | 100V, 200V (50/60Hz) | ||
| DC | 24V | |||
| Voltage fluctuation interval | ±10% | |||
| Starting current | AC | 100 V | 0, 032A / 0,027A | 0,068A / 0,054A |
| AC | 200V | 0,016A / 0,014A | 0, 034A / 0,027A | |
| DC | 24V | – | – | |
| Maintenance current | AC | 100V | 0,028A / 0,022A | 0, 041a / 0.032a |
| AC | 200V | 0,014A / 0,011A | 0,021A / 0,016A | |
| DC | 24V | 0,075A | 0,075A | |
| Electric consumption (With light indicator) | AC | 100V | 1,8W / 1,4W (2,0W / 1,6W) | 2,2W / 1,8W (2,4W / 2,0W) |
| AC | 200V | 1,8W / 1,4W (2,0W / 1,6W) | 2,2W / 1,8W (2,4W / 2,0W) | |
| DC | 24V | 1.8W (2.0W) | 1.8W (2.0W) | |
| Thermal class | B (damaged coil) | |||
| Temperature increase | 30 ℃ | |||
* 100 Vac 50/60 Hz can be used with a nominal voltage of 110 Vac 60 Hz and 200 Vac 50/60 Hz can be used with 220 Vac 60 Hz.
Flow characteristics
| Model | Puerto 1→2 | Puerto 2→1 | Puerto 2→3 | Puerto 3→2 | ||||
|---|---|---|---|---|---|---|---|---|
| C[dm²/(s-bar)] | b | C[dm²/(s-bar)] | b | C[dm²/(s-bar)] | b | C[dm²/(s-bar)] | b | |
| 3PA1 | 0,34 | 0,29 | 0,35 | 0,42 | 0,38 | 0,43 | 0,35 | 0,32 |
| 3Pa2 | 0,98 | 0,17 | 0 | 0,34 | 1,1 | 0,28 | 1 | 0,2 |
| 3PB1 | 0,37 | 0,05 | 0,33 | 0,21 | 0,41 | 0,28 | 0,42 | 0,08 |
| 3PB2 | 0,9 | 0,19 | 0,97 | 0,39 | 1 | 0,26 | 0,94 | 0,27 |