Description
■ Features
ITVX2000 series electro-pneumatic high pressure regulator provides continuous control of air pressure using electrical signals. Maximum supply pressure of 5.0 MPa. Continuous control of air pressure proportional to an electrical signal.
1. Continuous control of air pressure proportional to electrical signals
2. Sensitivity: 0.2 kPa (100 kPa specification)
3. Linearity: ±1% or less (F.S.)
4. Hysteresis: 0.5% or less (F.S.)
5. Wet parts: Fluorine grease
■ How to order ITVX2000 series high pressure electro-pneumatic regulator


■ Specs
| Model | ITVX2000 | |
|---|---|---|
| Min. pressure feeding | Whichever is greater: 0.5 MPa or the set pressure +0.2 MPa | |
| Max supply pressure | 5MPa*²) | |
| Pressure range*³) | 0.01 to 3.0 MPa | |
| Feeding | Strain | DC24V±10% |
| current consumption | 0.12A or less | |
| input signal | Current type*4) | DC4 a 20mA, DC0 a 20mA (tipo Sink) |
| Voltage type | DC0 a 5V, DC0 a 10V | |
| input impedance | Current type | 500Ω or less |
| Voltage type | 6 to 6.5 kΩ(at ordinary temperature) | |
Output signal*5) | analog output | DC1 to 5 V (Output impedance: Approx. 1 kΩ) Output accuracy: ±6% or less (full span) |
| DC4 at 20 mA (Sink type) Load impedance: 250Ω or less. Output accuracy: ±6% or less (full span) | ||
| switching output | NPN Open Collector Output: Max. 30V, 80mA Hysteresis: ±3% (full span), Self-diagnosis: ±5% or less (full span) | |
| PNP Open Collector Output: Max. 80mA Hysteresis: ±3% (full span), Self-diagnosis: ±5% or less (full span) | ||
| Linearity | ±1% or less (full span) | |
| Hysteresis | 1% or less (full span) | |
| Repeatability | ±1% or less (full span) | |
| Sensitivity | ±1% or less (full span) | |
| Temperature characteristics | ±0.12% or less (full span)/℃ | |
| Outlet pressure indication | Accuracy | ±2% or less (full span) ±1 digit |
| Min. units *6) | MPa: 0,01, kgf/cm²: 0,1, bar: 0,1, psi: 1 | |
| Working medium | Area, N₂, O₂, Ar | |
| Working temperature | 0 at 50℃ (No condensation) | |
| Weight | Approx.570g (No options) | |

*1) Characteristics indicated above based on the piping conditions in Fig. 1.
*2) When oxygen is used as a fluid, it should be supplied at a maximum pressure less than 1 MPa.
*3) Refer to Fig. 2 for the relationship between the set pressure and the input signal.
*4) 2-wire type DC4 at 20 mA is not available. Requires DC24 V supply voltage.
*5) Select analog output or switching output. Also, when switching output is selected, select NPN or PNP output.
When measuring the analog output of DC1 at 5V with load impedance less than 100 kΩ, the analog output may not achieve the output accuracy of ±6% or less (F.S.).
*6) Setting numerical values such as zero/span setting is set based on the minimum units for displaying outlet pressure.
Please note that the unit cannot be changed.
*7) This product is only for blowing gas. This product does not have sufficient pressure control for applications other than blowing (driving, sealing, etc.).
■ ITVX2000

■ Option/accessory type
| Description | Part No. | |
|---|---|---|
| Flat bracket (fixing screws included) | P398020-600 | |
| L Bracket Assembly (including mounting screws) | P398020-601 | |
| Power cord connector | Straight type 3m | P398020-500-3 |
| Right angle type 3m | P398020-501-3 | |

■ Dimensions


■ Cabling
▲ Caution
Connect the cable to the body connector with the wiring arranged as shown below.
Proceed with care, as incorrect wiring can cause damage.
Also, use a DC power supply with sufficient capacity and low ripple.

Note) There is also a right angle cable. A right angle type connector connects facing left (towards the SUP port). Do not try to turn it, as the connector does not rotate.
F.G. (Ground)
Ground the frame ground terminal (F.G.) located at the front of the main body. If the F.G. terminal port is not used, this product may not operate properly due to noise.

Current signal type / Voltage signal type
| 1 | Brown | Feeding |
|---|---|---|
| 2 | Blanco | input signal |
| 3 | Azul | GND (COMMON) |
| 4 | Negro | monitor output |

■ Monitor Output Wiring Diagram