Description
■ Features
Compact Electroneumatic Transducer ITV009 series provides continuous control of air/vacuum pressure proportional to an electrical signal.
1. Linearity: ±1% F.S. or less.
2. Hysteresis: 0.5% F.S. or less
3. Repeatability: ±0.5% F.S. or less
4. High speed response time: 0.1 s (without load)
5. High stability – Sensitivity: 0.2% F.S. or less
■ How to order ITV009 series compact electro-pneumatic transducer


■ Specs
| Model | ITV009□ | |
|---|---|---|
| Min. pressure feeding | Set pressure -1 kPa | |
| Max supply pressure | -101 kPa | |
| Adjusted pressure range | −1 to −100 kPa | |
| Feeding | Strain | DC24V±10%, DC12 a 15V |
| current consumption | Supply voltage type DC24 V 0.12 A or less Supply voltage type DC12 at 15 V: 0.18 A or less | |
| input signal | Voltage type | DC0 a 5V, DC0 a 10V |
| Current type | DC4 a 20mA, DC0 a 20mA (tipo Sink) | |
| input impedance | Voltage type | Aprox. 10 kΩ |
| Current type | Aprox. 250 kΩ | |
| Output signal*²) | analog output | DC1 to 5 V (Output impedance: Approx. 1 kΩ) Output accuracy ±6% F.S. or lower |
| Linearity | ±1% F.S. or less | |
| Hysteresis | 0.5% F.S. or less | |
| Repeatability | ±0.5% F.S. or less | |
| Sensitivity | 0,2% F.S. o inferior | |
| Temperature characteristics | ±0.12% F.S./℃ or less | |
| Working temperature | 0 at 50℃ (No condensation) | |
| Box | Equivalent to IP65*³) | |
| Connection type | Built-in One-touch fittings | |
| Connection size | For single unit | Metric size 1, 2, 3: Φ4 |
| Size in inches 1, 2, 3: Φ5/32”. | ||
| Collector | Metric 1, 3: Φ6, 2: Φ4 | |
| Size in inches 1, 3: Φ1/4”, 2: Φ5/32” | ||
| Peso * ¹) | 100g or less (no options) | |
*1) Indicates the weight of a single unit For IITV00-n
Total weight (g) ≤ Stations (n) × 100 + 130 (Weight of the end block assembly A, B) + Weight (g) of the DIN rail.
*2) When measuring ITV analog output at 1 to 5 VDC, if the load impedance is less than 100 kΩ, an analog output monitor accuracy of ±6% E.F. may not be available. or lower.
At the customer's request, the product is supplied with a precision of ±6%. The outlet pressure is not affected.
*3) When used under conditions equivalent to IP65, connect the fitting or tube to the breathing hole before use.
*4) When there is downstream flow consumption, the pressure may become unstable depending on the pipe conditions.
*5) When turning on the power, noise may be generated. This noise is normal and does not indicate any fault.
■ Serie ITV009□

■ Dimensions



*1) When used under conditions equivalent to IP65, connect the fittings or tube to the breathing hole before use.
*2) Refer to the cable connector dimensions on the individual unit.

| Distribution stations n | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
|---|---|---|---|---|---|---|---|---|---|
| L1 | 60 | 75 | 90 | 105 | 120 | 135 | 150 | 165 | 180 |
| L2 | 110,5 | 123 | 148 | 160,5 | 173 | 185,5 | 198 | 223 | 235,5 |
| DIN rail weight [g] | 20 | 22 | 27 | 29 | 31 | 34 | 36 | 41 | 43 |