Description
■ Features
1. Enhanced VP-02 series digital pressure sensor designed for maximum cost effectiveness
2. Built-in basic leak detection function
3. Basic integrated algorithm for vacuum and suction control
4. Built-in ultra-fast leak detection function
5. Ultra-fast response of digital output
■ Specs
| Model | VP-01/02/04P (High pressure type) | VP-01/02/04C (Low pressure type) | VP-10P (High pressure type) | VP-10C (Low pressure type) | VP-15/04P (High pressure type) | VP-15/04C (Low pressure type) | |
|---|---|---|---|---|---|---|---|
| Nominal pressure range | -0,101–1,0 MPa | -101,3–101,3 kPa | -0,101–1,0 MPa | -101,3–101,3 kPa | -0,101–1,0 MPa | -101,3–101,3 kPa | |
| Adjustable pressure range | -0,105–1,0 MPa | -105–105 kPa | -0,105–1,0 MPa | -105–105 kPa | -0,105–1,0 MPa | -105–105 kPa | |
| Test pressure | 1,5 MPa | 500 kPa | 1,5 MPa | 500 kPa | 1,5 MPa | 500 kPa | |
| Applicable fluid | Non-corrosive and non-combustible gases; conforming to ISO 8573-1:2010 [7:4:4] | ||||||
| Supply voltage | 12-24 V DC ±10% | ||||||
| current consumption | 45mA max (no load) | ||||||
| Display resolution according to pressure unit | kPa | 1 | 0,1 | 1 | 0,1 | 1 | 0,1 |
| MPa | 0,001 | — | 0,001 | — | 0,001 | — | |
| kgf/cm² | 0,01 | 0,001 | 0,01 | 0,001 | 0,01 | 0,001 | |
| bar | 0,01 | 0,001 | 0,01 | 0,001 | 0,01 | 0,001 | |
| psi | 0,1 | 0,01 | 0,1 | 0,01 | 0,1 | 0,01 | |
| mmHg | — | 1 | — | 1 | — | 1 | |
| inHg | — | 0,1 | — | 0,1 | — | 0,1 | |
| Digital output *1 | NPN open collector output Max current Load: 100 mA Max voltage Power: 30V DC Internal tension fallen: 1.5 V the least | PNP open collector output Max current Load: 100 mA Max voltage Power: 24V DC Internal tension fallen: 1.5 V the least | |||||
| Analog voltage output *1 | Output voltage: 1–5 V ±2.5% F.S. Linearity: ±1% F.S. Output impedance: approx. 1 kΩ | Output voltage: 1–5 V ±2.5% F.S. Linearity: ±1% F.S. Output impedance: approx. 1 kΩ | Not available | ||||
| Analog current output *1 | Not available | Output current: 4–20 mA ±2.5% F.S. Linearity: ±1% F.S. Load resistance: max. 300 Ω to 12 V; 600 Ω to 24 V | Not available | ||||
| MODBUS function *2 | Not available | Available | |||||
| Display Accuracy | ±2% F.S. ±1 digit (at 25 ±3°C) | ||||||
| Repeatability | ±0.2% F.S. ±2 digits | ||||||
| Response time | 2.0 ms, 50 ms, 100 ms, 250 ms, 500 ms, 2000 ms, 3000 ms, 5000 ms selectable | 1 ms, 2.0 ms, 50 ms, 100 ms, 250 ms, 500 ms, 2000 ms, 3000 ms, 5000 ms selectable *3 | 2.0 ms, 50 ms, 100 ms, 250 ms, 500 ms, 2000 ms, 3000 ms, 5000 ms selectable | ||||
| Screen | 3-color display (red, orange and yellowish green); Sampling rate: 4 times/s | ||||||
| Temperature characteristics | ±2% F.S. (reference temperature: 25°C; within the operating range of 0–50°C) | ||||||
| Operating environment | 0–50°C (no condensation or freezing); 35–85% RH (non-condensing) | ||||||
| Storage environment | -10–50°C (no condensation or freezing); 35–85% RH (non-condensing) | ||||||
| Protection degree | IP40 | ||||||
| Connection/pipe specification | Female thread: M5 Male thread: R1/8 (Asian standard, BSPT 1/8) Direct instant fitting: optional for Ø4 mm or Ø6 mm tube; straight or 90° elbow | ||||||
| Weight | Approx. 70g (including power cord) | Approx. 85g (including power cord) | |||||
| Accessories | 1 power cable with terminals | ||||||
*1) VP-02 series enhanced digital pressure sensor, the output type directly corresponds to the product model.
*2) Only VP-15 series supports MODBUS mode.
*3) SUPERSPEED mode must be enabled to support 1ms response time.