Description
■ Specs
| Model | PSE540 | PSE541 | PSE543 | |
|---|---|---|---|---|
| Nominal pressure range | 0 1 MPa | 0 a -101 kP | -100 a 100 kPa | |
| Test pressure | 1,5 MPa | 500 kPa | ||
| Working medium | Non -flammable non -corrosive air/gas | |||
| Supply voltage | DC12 to 24 V ± 10%, Ripple (P-P) 10% or less (with inverse connection protection) | |||
| current consumption | 15 ma o menos | |||
| Output specifications | Analog output: 1 to 5V (within the nominal pressure range), 0, 6 to 1V (within the analog extension output range) | |||
| Departure impedance: approx. 1kΩ | ||||
| Precision (Environment temperature at 25 ℃) | PSE54□: ±2%F.S. (within rated pressure ), ±5%F.S. (within extension analog output) PSE54□A: ±1%F.S. (within rated pressure ), ±3%F.S. (within extension analog output) | |||
| Linearity | ± 0.7% f.s. The least | ±0.4% F.S. | ||
| Repeatability | ±0.2% F.S. | |||
| Effect of food voltage | ±0.8% F.S. | |||
| Environment | Box | IP40 | ||
| Operating temperature | In operation: 0 to 50 ℃, stored: -20 to 70 ℃ (without freezing or condensation) | |||
| Operating humidity | In operation/at rest: 35 to 85% HR (without condensation) | |||
| Withstand voltage | AC 1000V (in 50/60Hz) for 1 minute between terminals and housing | |||
| insulation resistance | 50MΩ or more (500V CC measured by megóhter) between terminals and housing | |||
| Temperature characteristics | ±2% F.S. (reference 25℃) | |||
| Sensor cable | Oil resistant vinyl cable (ellipse), 3 drivers, 2.7 × 3.2, 3m Driver area 0.15 mm², outer diameter of the insulator: 0.9 mm | |||
■ Internal circuit and wiring example

■ analog output

| Gama | Nominal pressure range | A | B | C |
|---|---|---|---|---|
| For vacuum pressure | 0 a -101,0 kPa | 0 kPa | -101,0 kPa | 10,1 kPa |
| For composite pressure | -100,0 a 100,0kPa | -100,0 kPa | 101,0 kPa | ― |
| For positive pressure | 0 a 1,0MPa | 0 kPa | 1,0 MPa | -0,1 MPa |
■ Dimensions