Description
■ Features
1. Pressure sensors for general fluids The PSE560 series is for the pressure range of a standard pneumatic system, while the PSE564 model is for low pressure.
2. Remote pressure sensor for liquids or gases at 1 mpa or less.
3. Includes a fixed cable with a field wiring connector.
4. Without oil (simple diaphragm construction), degree of protection IP65.
■ How to order PSE560 and PSE564 Series Pressure sensors for general fluids

Option/Part No.
| Description | Part No. | Material | Use |
|---|---|---|---|
| Pressure sensor control connector | Zs-28-C | — | 1pc. |
| RC1/4 restrictor adapter | ZS-31-X175 | 304 stainless steel | 1pc. |
| NPT1/4 | ZS-31-X186 | 1pc. | |
| RC1/8 | Zs-31-X188 | 1pc. | |
| NPT1/8 | Zs-31-X189 | 1pc. | |
| M5 hole | Zs-48-A | 303 stainless steel | 1pc. |
■ Specs
| Model | PSE560 (Positive pressure) | Dog561 (pressure vacuum) | PSE563 (Composite pressure) | PSE564 (Positive pressure) |
|---|---|---|---|---|
| Nominal pressure range | 0 a 1MPa | 0 a -101kPa | -100 a -100kPa | 0 a 500kPa |
| Extension analog output range | -0,1 a 0MPa | 10,1 a 0kPa | – | -50 a 0kPa |
| Test pressure | 1,5MPa | 500kPa | 500kPa | 750kpa |
| Model | PSE56□-□ | PSE56□-□-28 | |
|---|---|---|---|
| Working medium | Liquid or gas that does not run or attack the 316L stainless steel | ||
| Supply voltage | DC12 to 24 V ± 10%, Ripple (P-P) 10% or less (with inverse connection protection) | ||
| current consumption | 10 ma o menos | — | |
| Output specifications | Analog output: 1 to 5V (within the nominal pressure range) 0, 6 to 1V (within the analog extension output range) | Analog output: DC4 to 20 mA (within the nominal pressure range) | |
| Departure impedance: approx. 1kΩ | Maximum load impedance: 500Ω the least (the dc24 v) 100Ω the least (A DC12 V) | ||
| Precision (Environment temperature at 25 ℃) | ± 1%ESF (within the nominal pressure range), ± 3%ESF (within the analog extension output range) | ||
| Linearity | ±0.5% F.S. | ||
| Repeatability | ±0.2% F.S. | ||
| Effect of food voltage | ±0.3% F.S. | ||
| Half environment | Box | IP65 | |
| Temperature of operation | Operation: 10 to 60 ℃, stored: -20 to 70 ℃ (without freezing or condensation) | ||
| Humidity of operation | Operation/storage: 35 to 85% HR (without condensation) | ||
| Withstand voltage | AC250V for 1 minute between terminals and housing | ||
| Endurance Isolation | 50MΩ or more (50V CC measured by megóhter) between the terminals and the housing | ||
| Temperature characteristics | ±2% F.S. (0 50°C: 25°C Reference), ±3% F.S. (-10 60°C: 25°C Reference) | ||
| Sensor cable | PSE56 -: Oil resistant vinyl cable, 3 conductors, φ5.1, 3 m, Driver Area: 0.2 mm², D.E. of the insulator: 1.12 mm | ||
| PSE56 --28: Oil resistant vinyl cable with air tube, 2 conductors, φ5,1, 3 m, Driver Area: 0.2 mm², D.E. of the insulator: 1.12 mm | |||
| Pipe material | Box: C3604 + Niquelado, Pipe port/pressure sensor: 316L stainless, fat without fat | ||
| Norms | Marked CE (Directive CEM/ROHS Directive), UL/CSA (E216656) | ||
■ Option/Part No.

■ analog output

| Gama | Nominal pressure range | A | B | C |
|---|---|---|---|---|
| For vacuum pressure | 0 a -101 kP | 0 kPa | -101 kPa | 10,1 kPa |
| For composite pressure | -100 a 100kPa | -100 kPa | 100 kPa | ― |
| In case of positive pressure | 0 a 1MPa | 0 kPa | 1 MPa | -0.1 MPa |
| 0 a | 0 kPa | 500 kPa | -50 kPa |
■ Dimensions

* Dimensions of part C common to all PSE56 models.
* Be sure to release the air from the cable air tube to the atmosphere. If the air tube is restricted, or is left in environments in which it is exposed to water or oil, it cannot be detected normally.