Description
■ Features
1. DIGITAL FLOWS FOR WATER PF3W Water Visualization in 3 colors/2 screens.
2. Type of integrated screen, separate type of monitor and type of PVC pipe.
3. Reduced required pipe space.
4. Swiller screen: 90 ° in antihorario direction, 225 ° in a schedule. The screen can be rotated in 45 ° increases to adapt to installation conditions.
5. Easy handling, improved visibility. New PF3W721-14- -M model. (Adjustable flow of 20-350L/min).
■ How to order PF3W Digital flow series for water


■ Specs
| Model | PF3W704 | PF3W720 | PF3W740 | PF3W711 | P3W721 | |
|---|---|---|---|---|---|---|
| Working fluid | Aqueous solution of water and ethylene glycol (with a viscosity of 3 mPa s [3 cP] or less) | |||||
| Detection method | Vórtice de Kármán | |||||
| Nominal flow range | 0.5 to 4 l/min | 2 to 16 L/min | 5 to 40 L/min | 10 to 100 L/min | From 50 to 250 l/min | |
| Flow range on display *1) | 0.35 to 5.5 l/min | 1.7 to 22.0 L/min | 3.5 to 55.0 l/min | 7 to 140.0 L/min | From 20 to 350.0 l/min | |
| Flow adjustment range | 0.35 to 5.5 l/min | 1.7 to 22.0 L/min | 3.5 to 55.0 l/min | 7 to 140.0 L/min | From 20 to 350.0 l/min | |
| Minimum adjustment increment | 0.01 l/min | 0.1 L/min | 0.1 l/min | 1 L/min | 2 l/min | |
| Conversion of accumulated pulses (Pulse width: 50 ms) | 0.05 l/pulse | 0.1 L/pulse | 0.5 l/pulse | 1 L/pulse | 2 l/pulse | |
| Fluid temperature | 0 to 90°C (no freezing or condensation) | 0 to 70°C (no freezing or condensation) | ||||
| Visualization unit | Instant flow: l/min, accumulated flow: l | |||||
| Precision | Display value: ±3% F.S. Analog output: ±3% F.S. | |||||
| Repeatability | ±2 % F.S. *2) | |||||
| Temperature characteristics | ±5% F.S. (standard at 25°C) | |||||
| Working pressure | 0 1 MPa | |||||
| Test pressure | 1,5 MPa | |||||
| Pressure loss (Without flow regulation valve) | 45 kpa or less to the maximum flow | 60 kpa or less to the maximum flow | ||||
| Accumulated flow rate *3) | 99999999,9 L | 999999999 L | ||||
| For 0.1L | For 0.5L | For 0.1L | ||||
| switching output | NPN or PNP open collector output | |||||
| Max charging current | 80 mA | |||||
| Max applied voltage | 28 V CC | |||||
| Internal tension drop | NPN: 1 V or less (with 80 mA load current); PNP: 1.5V or less (with 80mA charging current) | |||||
| Response time *2),4) | 0,5 s / 1 s / 2 s | |||||
| Output protection | Short circuit protection | |||||
| Output mode | Caudal | Selection between modes: hysteresis, window comparator, accumulated output or accumulated pulse output. | ||||
| Temperature | Selection between hysteresis mode or window comparator mode | |||||
| analog output | Response time *5) | 0.5s / 1s / 2s (tied to switch output) | ||||
| Voltage output | Output voltage: 1 to 5 V; Output impedance: 1 kΩ | |||||
| Current output | Output current: 4 to 20 mA; Max. Load Impedance: 300 Ω for 12 VDC, 600 Ω for 24 VDC | |||||
| Hysteresis | Variable | |||||
| External entrance | Voltage-free input: 0.4 V or less (Reed or solid state), input for 30 ms or more | |||||
| Display method | 2-line display (Main display: 4 digits, 7 segments, 2 colors [red/green]; Secondary display: 6 digits, 11 segments, white) | |||||
| Light indicator | Departure 1, Orange: Orange | |||||
| Supply voltage | 12 a 24 V CC ±10% | |||||
| current consumption | 50 ma o menos | |||||
| Environment | Housing | IP65 | ||||
| Operating temperature | 0 to 50°C (no freezing or condensation) | |||||
| Operating humidity | Operation and storage: 35 to 85% RH (non-condensing) | |||||
| Withstand voltage *6) | 1000 VAC for 1 minute between terminals and case | |||||
| insulation resistance | 50 MΩ or more (500 V DC, measured with megohmmeter) between terminals and case | |||||
| Standards and regulations | Marked CE (EMC directive/RoHS directive), UL (CSA) | |||||
| Material of parts in contact with the fluid | PPS, FKM, SCS13, SUS304; sin grasa | |||||
| Pipe connection size *7) | 3/8 | 3/8, 1/2 | 1/2, 3/4 | 3/4, 1 | 1 1/4, 1 1/2 | |
*1) When the actual flow rate is lower than the minimum flow rate display range, the display will show “0.00”, “0.0” or “0”.
*2) If 0.5 s is selected as the switch output response time, the repeatability will be ±3% of full scale (F.S.).
*3) Cleared when power is turned off. Hold function can be selected. (2 or 5 minute intervals can be selected).
If the 5 minute interval is selected, the life of the memory element (electronic components) is limited to 1 million cycles.
(If it remains energized 24 hours, the lifespan is calculated as: 5 minutes × 1 million = 5 million minutes = approx. 9.5 years.)
Therefore, if you use the retention function, calculate the memory life according to your operating conditions and use it within that limit.
*4) Response time until reaching 90% of the set value with respect to a step input (the response time is 7 s for the temperature sensor output).
*5) Response time until reaching 90% of the set value with respect to a step input (the response time is 7 s for the analog output of the temperature sensor).
*6) In the case of the temperature sensor, the withstand voltage is 250 V AC.
*7) If the pipe diameter or pitch is restricted, the specifications may not be met.
*8) Products that have small scratches, marks or variations in the color or brightness of the screen, as long as they do not affect the performance of the product, are considered compliant.
■ Options/Part #
If you only need optional pieces, make your order with the piece numbers indicated below.
| Description | Part No. | Qty. | Use | |
|---|---|---|---|---|
| Medium* | Zs-40s | 1 | For PF3W704/720/504/520 | With 4 thread screws (3 × 8) |
| ZS-40-L | 1 | For PF3W740/540 | With 4 thread screws (3 × 8) | |
| Zs-40-M | 1 | For PF3W711/511 | With 4 thread screws (4 × 10) | |
| M8 connector cable | ZS-40-A | Cable length: 3 m | ||
* For units with flow adjustment valve, 2 supports are required.
■ Flow/analog output
| Symbol | Output voltage | Output current | |
|---|---|---|---|
| PF3W704/720/740 | A | 1V | 4MA |
| B | 1,5V | 6ma | |
| C | 5V | 20mA | |
| (PF3W711) | A | 1V | 4MA |
| B | 1,4V | 5,6ma | |
| C | 5V | 20mA | |
| P3W721 | A | 1V | 4MA |
| B | 1.8V | 7,2MA | |
| C | 5V | 20mA | |
| Model | Caudal nominal [L/min] | |
|---|---|---|
| Mini. | Max. | |
| PF3W704/504 | 0,5 | 4 |
| PF3W720/520 | 2 | 16 |
| PF3W740/540 | 5 | 40 |
| PF3W711/511 | 10 | 100 |
| PF3W721/521 | 30 | 250 |

■ Dimensions