PF2A series digital air flow switch, integrated type

1. PF2A is suitable for applications that require an air measurement, such as supply confirmation, filling accumulation or fixed supply consumption.
2. Possibility of turning the screen in increases of 90 degrees, which offers a better visibility of the operation.
3. The thermal sensor is protected in a derivation flow path to reduce contact with moisture and pollutants, avoiding the deterioration and accuracy damage.
4. The PF2A has an IP65 degree of protection and meets the ROHS and CE standards.

Description

■ Features

1. Adjustment and control of the flow are possible with the digital screen.
2. Digital air flows for integrated PF2A series and separate types of monitor are available.
3. Three types of output: switch, accumulated pulse and analog outputs.
4. capable of alternating between accumulated and instant flow.
5. 4 channel flow monitor: 4 independent flow ranges can be monitored by a single controller.

■ How to order PF2A Air Digital Flowers Series

Digital air flow switch

■ Specs

ModelPF2A710Pf2a750Pf2a711Pf2a721Pf2a751
Working mediumDry air, nitrogen
Caudal nominal1 to 10 l/min5 to 50 l/min10 to 100 l/min20 a 200L/min50 a 500L/min
Minimum adjusted unit0, 1l/min0, 5L/min1l/min2l/min5l/min
Exchange value of the accumulated impulse flow
(Pulse width: 50 ms)
0, 1l/pulse0, 5L/Pulso1l/pulse2L/PULSO5L/PULSO

Visualization units*¹, ²)

Instant flowL/min, CFM × 0.01L/min, CFM × 0.1
Accumulated flowL, ft³×0.1
Working temperature0 a 50℃
Precision*³)±5%F.S.
Repeatability±1%F.S.±2%F.S.
Temperature characteristics± 3%es.f. (15 to 35 ℃, 25 ℃ Reference), ± 5%es.f. (0 to 50 ℃, 25 ℃ reference)
current consumption150 ma o menos160 ma o menos170 ma o menos
Port size (RC, NPT, G)1/8, 1/43/81/2
Type of detectionType of heater
Operating pressure-50kPa a 0,5MPa-50kPa a 0,75MPa
Test pressure1,0MPa
Accumulated flow range*4)0 A 999999L

Output specifications*5)

switching outputCollector
NPN Open
Max.: 80 Ma;
Internal tension fallen: 1 V the least
Max. Applied: 30 V; 2 outputs
Collector
Open PNP
Max.: 80 Ma;
Internal tension drop: 1.5 v or less; 2 outputs
Accumulated impulse outputNPN or PNP open collector (just like switch outlet)
State LEDIt is illuminated when the exit is on Out1: green; Out2: Red
Response time1 sec. less
HysteresisHysteresis: variable (can be adjusted from 0),
Window comparator: 3 fixed digits
Supply voltageDC12 a 24 V±10%
EnvironmentBoxIP65
Working temperatureIn operation: 0 to 50 ℃, stored: -25 to 85 ℃
(without freezing or condensation)
Withstand voltageCA 1000V for 1 minute between terminals and housing
insulation resistance50MΩ or more (500V CC measured by megóhmmeter)
between terminals and housing
Noise resistancePulse width of 1000V P-P1μS lasts 1ns

*1) Digital flow switch with units switching function. (The unit if it sets [(l/min, or l, m³ or m³ × 10³)] will be established for the type of switch without the commutation function of units).
*2) Flow screen can be changed between the basic condition of 0 ℃, 101.3 kPa and the standard condition (ANR) of 20 ℃, 101.3 kPa, and 65% HR.
*3) The tubes on the inlet side must have a straight section of the pipe whose length is 8 times the diameter of the pipe or more. If a straight pipe section is not installed, the precision can vary in ± 5% F.S. or more.
*4) Accumulated capacity is restarted when the power supply is turned off.
*5) Switching and exit of selectable accumulated impulses during the initial adjustment.
*6) Window comparator - since hysteresis will reach 3 digits, keep P_1 and P_2 or N_1 and N_2 separated by 7 digits or more. (In the case of out2, N_1, 2 must be N_3, 4 and P_1, 2 must be P_3, 4.)
*7) Digital air flows for more details on wiring and thread type, contact VPC.
*8) Any product with small scratches, spots or variations in the color or brightness of the screen that do not affect performance is verified as a compliant product.

■ analog output

Part No.My caudal nominal.Maximum nominal flow value
PF2A7101NL/min10nl/min
3,5CFM×0,0135,0CFM×0,01
Pf2a7505nl/min50NL/min
18,0CFM×0,01176,0CFM×0,01
Pf2a71110nl/min100NL/min
3,5CFM×0,135,5CFM×0,1
Pf2a72120nl/min200NL/min
7,0CFM×0,171,0CFM×0,1
Pf2a75150NL/min500NL/min
18,0CFM×0,1176,0CFM×0,1

* When you use the analog output of the standard state, conversion according to the following formula.
Value of the base state flow ÷ 0.927 = value of the standard state flow.

Digital air flows SMC