Skip to content Skip to footer

PF2A series high flow digital flow switch

1. Type of high PF2A flow is suitable for applications that require an air measurement, as for supply confirmation, filling accumulation or fixed supply consumption.
2. It has a rotating screen in increases of 90 degrees, which offers a better visibility of the operation.
3. This thermal sensor is protected in a derivation flow path to reduce contact with moisture and pollutants, avoiding the deterioration and accuracy damage.
4. In addition, the PF2A has an IP65 degree of protection and meets the ROHS and CE standards.

Description

■ Features

1. Digital flow for large flow PF2A series PF2A is suitable for applications that require an air measurement, as for supply confirmation, filling accumulation or fixed supply consumption.
2. It has a rotating screen in increases of 90 degrees, which offers a better visibility of the operation.
3. This thermal sensor is protected in a derivation flow path to reduce contact with moisture and pollutants, avoiding the deterioration and accuracy damage.
4. In addition, the PF2A has an IP65 degree of protection and complies with the ROH and CE standards.

■ How to order PF2A Digital flow series for large flow

Digital flow for liquids

■ Specs

ModelPf2a703hPf2a706hPf2a712h
Working mediumDry air, nitrogen
Type of detectionType of heater
Nominal flow range*¹)150 a 3000L/min300 a 6000L/min600 a 12000L/min
Minimum unit*¹)5l/min10l/min
Visualization units*²)Instant flowL/min, CFM
Accumulated flowL, m³, m³×10³, ft³, ft³×10³, ft³×106
Service pressure0,1 a 1,5MPa
Test pressure2,25MPa
Loss of load20KPA (to maximum flow)
Accumulated flow margin*³)0 a 9,999,999,999L
Precision*5)±1,5%F.S. (0,7MPa, a 20℃)
Repeatability± 1.0% F.S. (0.7MPA, at 20 ℃), ± 3.0% F.S. In case of analog output
Pressure characteristics± 1.5% f.s. (0.1 to 1.5 MPa, reference 0.7 MPa)
Temperature characteristics±2.0% F.S. (0 to 50th, 25th of reference)
Output specificationsSwitching output*5)NPN open collectorMax. of load: 80 mA;
Max. Applied: 30 v
Internal tension fallen: 1 V the least
(with 80 mA load current)
PNP Open Collector Max. of load: 80 mA;
Internal tension fallen: 1.5 V the least
output of
accumulated impulses*5)
NPN or PNP open collectorPulse flow: 100 l/pulse, 10.0 ft³/pulse
Time on Pulse width: 50 mseg/pulse
Analog output*6)Output voltage: 1 to 5 V;
Minimum load impedance: 100 kΩ (output impedance: 1 kΩ)
Output current: 4 to 20 mA; Max.: 250 Ω load impedance
Response time1 sec. less
HysteresisHysteresis: variable (can be adjusted from 0);
Window comparator: fixed (can be adjusted from 0 to 3% F.S.)
Supply voltageDC24 V±10%
current consumption450 ma o menos
AroundBoxIP65
Working temperature0 at 50 ℃ (without freezing or condensation)
Withstand voltageAC 1000V for 1 minute between terminals and housing
insulation resistance50MΩ or more (500V CC measured by megóhmmeter)
between terminals and housing
Noise resistance1000V P-P wide pulse1μs hard 1ns
Standards and regulationsCE, RoHS
Weight1.1 kg (without cable)1 kg (sin cable conductor)2 kg (sin cable conductor)
Port size (RC, NPT, G)11 1/22

*1) Visualization of the switching flow between the basic condition of 0 ° C, 101.3 kPa and the standard condition (ANR) of 20 ° C, 101.3 kPa and 65% HR.
*2) For digital flow switch with units switching function. (The unit if it sets [(l/min, or l, m³ or m³ × 10³)] will be established for the type of switch without the commutation function of units).
*3) Accumulated flow rate is restored when the power supply turns off. It is possible to select a function that retains the accumulated value so that it does not restart. In this case, the data is written in EEPROM (electrically programmable and erasure reading only) at intervals of approximately four minutes. When using it, keep in mind that the writing in Eeprom is guaranteed up to 1 million times (four minutes × 1 million = 4 million ≈ 7.9 years).
*4) high flow type is compatible with the CE brand; However, the linearity with applied noise is ± 5% F.S. or less.
*5) Switching output and accumulated pulse output selections are made using button controls.
*6) Only the analog output for instant flow rate works, and does not work for accumulated flow.

■ Flower characteristics (pressure loss)

Digital air flows SMC

■ Dimensions

analog output
SMC digital flowmeter
Digital air flow switch

PDF Catalog